IPX5,IPX6防水方法测试英文翻译

JUMU实名认证 发表于 2019-10-22 21:50 | 显示全部楼层 | 复制链接分享      上一主题  翻页  下一主题
IPX5 test method:
1. Nozzle inner diameter: 6.3 mm;
2. Water flow rate: 12.5 L/min;
3. Water pressure: according to the regulation of water flow;
4. the surface of the enclosure spray water (per square meter): about 1 min;
6, the distance from the nozzle to the surface of the enclosure: 2.5-3 m;
7. Test time: at least 3 minutes.

IPX6 test method:
1. Nozzle inner diameter: 12.5 mm (IPX6)
2. Water flow rate: 100±5 L/min (IPX6)
3. Water pressure: according to the regulation of water flow;
4. the surface of the enclosure spray water (per square meter): about 1 min;
6, the distance from the nozzle to the surface of the enclosure: 2.5-3 m;
7. Test time: at least 3 minutes.

IPX5-IPX6 Test Report.docx

文件大小:2.91 MB

售价: 20 积分 [购买]

  距米网  

找到您想要的设计

工程师、学生在线交流学习平台
关注我们

手机版- 距米网 |苏公网安备32041102000587号

© 2017-2025 居居米 苏ICP备18040927号-1